Knowledge Agora



Scientific Article details

Title Lithium-ion battery recycling: a source of per- and polyfluoroalkyl substances (PFAS) to the environment?
ID_Doc 13231
Authors Rensmo, A; Savvidou, EK; Cousins, IT; Hu, XF; Schellenberger, S; Benskin, JP
Title Lithium-ion battery recycling: a source of per- and polyfluoroalkyl substances (PFAS) to the environment?
Year 2023
Published Environmental Science-Processes & Impacts, 25, 6
DOI 10.1039/d2em00511e
Abstract Recycling of lithium-ion batteries (LIBs) is a rapidly growing industry, which is vital to address the increasing demand for metals, and to achieve a sustainable circular economy. Relatively little information is known about the environmental risks posed by LIB recycling, in particular with regards to the emission of persistent (in)organic fluorinated chemicals. Here we present an overview on the use of fluorinated substances - in particular per- and polyfluoroalkyl substances (PFAS) - in state-of-the-art LIBs, along with recycling conditions which may lead to their formation and/or release to the environment. Both organic and inorganic fluorinated substances are widely reported in LIB components, including the electrodes and binder, electrolyte (and additives), and separator. Among the most common substances are LiPF6 (an electrolyte salt), and the polymeric PFAS polyvinylidene fluoride (used as an electrode binder and a separator). Currently the most common LIB recycling process involves pyrometallurgy, which operates at high temperatures (up to 1600 degrees C), sufficient for PFAS mineralization. However, hydrometallurgy, an increasingly popular alternative recycling approach, operates under milder temperatures (<600 degrees C), which could favor incomplete degradation and/or formation and release of persistent fluorinated substances. This is supported by the wide range of fluorinated substances detected in bench-scale LIB recycling experiments. Overall, this review highlights the need to further investigate emissions of fluorinated substances during LIB recycling and suggests that substitution of PFAS-based materials (i.e. during manufacturing), or alternatively post-treatments and/or changes in process conditions may be required to avoid formation and emission of persistent fluorinated substances.
Author Keywords
Index Keywords Index Keywords
Document Type Other
Open Access Open Access
Source Science Citation Index Expanded (SCI-EXPANDED)
EID WOS:000989460200001
WoS Category Chemistry, Analytical; Environmental Sciences
Research Area Chemistry; Environmental Sciences & Ecology
PDF https://pubs.rsc.org/en/content/articlepdf/2023/em/d2em00511e
Similar atricles
Scroll