Title Influence of HFM Thermal Contact on the Accuracy of In Situ Measurements of Facades' U-Value in Operational Stage
ID_Doc 63990
Authors Gaspar, K; Casals, M; Gangolells, M
Title Influence of HFM Thermal Contact on the Accuracy of In Situ Measurements of Facades' U-Value in Operational Stage
Year 2021
Published Applied Sciences-Basel, 11, 3
DOI 10.3390/app11030979
Abstract Accurate information on the actual thermal transmittance of walls is vital to select appropriate energy-saving measures in existing buildings to meet the commitments of the European Green Deal. To obtain accurate results using the heat flow meter (HFM) method, good thermal contact must be made between the heat flow meter plate and the wall surface. This paper aimed to assess the influence of the non-perfect thermal contact of heat flow meter plates on the accuracy of in situ measurement of the facades' U-value when a film was applied to avoid damage to the wall surface. Given the fact that to avoid harm to the wall surface, the laying of a film is a usual procedure in the installation of equipment during the building's operational stage. The findings show that deviations between measured U-values when an HFM was installed directly on the wall surface and when an HFM was installed with a PVC film were found to differ significantly from the theoretical effect of including a PVC film during the monitoring process.
Author Keywords non-destructive test; monitoring; housing; buildings; faç ade; thermal transmittance; HFM method
Index Keywords Index Keywords
Document Type Other
Open Access Open Access
Source Science Citation Index Expanded (SCI-EXPANDED)
EID WOS:000615013900001
WoS Category Chemistry, Multidisciplinary; Engineering, Multidisciplinary; Materials Science, Multidisciplinary; Physics, Applied
Research Area Chemistry; Engineering; Materials Science; Physics
PDF https://www.mdpi.com/2076-3417/11/3/979/pdf?version=1611299877
Similar atricles
Scroll